Line 11: | Line 11: | ||
Copy the user environment design to your chosen parent directory (e.g ~/ihp) and set general Cadence environment variables by doing: | Copy the user environment design to your chosen parent directory (e.g ~/ihp) and set general Cadence environment variables by doing: | ||
cp -rp /eda/design_kits/ihp_sg13/SG13S_616_rev1. | cp -rp /eda/design_kits/ihp_sg13/SG13S_616_rev1.5.0_a/work/skel ~/ihp | ||
source /eda/cadence/2016-17/scripts/analog_flow.sh | source /eda/cadence/2016-17/scripts/analog_flow.sh | ||
Change sh.cadence in ~/ihp | Change sh.cadence in ~/ihp/cds to suit your needs. In particular you must define $IHP_TECH and $PROJECT according to your local environment | ||
cd ~/ihp/cds/ | |||
source sh.cadence | |||
Start the design environment by: | Start the design environment by: |
Revision as of 15:01, 20 April 2017
Cadence design with IHP 130nm process
Starting up the IHP SG13S Design Kit
The following steps describe how to install the Process Design Kit and start a new design.
Log on to one of the mikroservers:
ssh -X mikroserver2
The preferred shell is bash. When using another shell it will be necessary to change the installation routine and modify the initialization script accordingly.
Copy the user environment design to your chosen parent directory (e.g ~/ihp) and set general Cadence environment variables by doing:
cp -rp /eda/design_kits/ihp_sg13/SG13S_616_rev1.5.0_a/work/skel ~/ihp source /eda/cadence/2016-17/scripts/analog_flow.sh
Change sh.cadence in ~/ihp/cds to suit your needs. In particular you must define $IHP_TECH and $PROJECT according to your local environment
cd ~/ihp/cds/ source sh.cadence
Start the design environment by:
virtuoso &
Follow the Design Kit User manual found in the menu SG13S Features > Design Kit Documentation. Make sure that your web browser is closed or started from the microserver, else the file will not be found.